datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

DM9161CI Ver la hoja de datos (PDF) - Davicom Semiconductor, Inc.

Número de pieza
componentes Descripción
Lista de partido
DM9161CI Datasheet PDF : 47 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
DM9161CI
10/100 Mbps Fast Ethernet Physical Layer Single Chip Transceiver
5.2 Media Interface
Pin No.
Pin Name
3,4
RX+
RX-
7,8
TX+
TX-
5.3 LED Interface
Pin No.
11
Pin Name
LED0
/OP0
12
LED1
/OP1
13
LED2
/OP2
5.4 Mode
Pin No.
10
Pin Name
PWRDWN
14
CABLESTS
/LINKSTS
39
DISMDIX
45
NC
I/O
Description
I/O Differential Receive Pair
Differential data is received from the media
I/O Differential Transmit Pair/PECL Transmit Pair
Differential data is transmitted to the media in TP mode
PECL data is transmitted to the media in Fiber mode
I/O
Description
O, LED Driver output 0
LI OP0: (power up reset latch input)
(U) This pin is used to control the forced or advertised operating mode of the
DM9161CI according to the Table A. The value is latched into the
DM9161CI registers at power-up/reset
O,
LI LED Driver output 1
(U) OP1: (power up reset latch input)
This pin is used to control the forced or advertised operating mode of
the DM9161CI according to the Table A. The value is latched into the
DM9161CI registers at power-up/reset
O, LED Driver output 2
LI OP2: (power up reset latch input)
(U) This pin is used to control the forced or advertised operating mode of the
DM9161CI according to the Table A. The value is latched into the
DM9161CI registers at power-up/reset
I/O
Description
I Power Down Control
Asserted high to force the DM9161CI into power down mode. When in
power down mode, most of the DM9161CI circuit block’s power is
turned off, only the MII management interface (MDC, MDIO) logic is
available (the PHY should respond to management transactions and
should not generate spurious signals on the MII)). To leave power down
mode, the DM9161CI needs the hardware or software reset with the
PWRDWN pin low
O, Cable Status or Link Status
LI This pin is used to indicate the status of the cable connection when
(D) power up reset latch low (Default)
0 = Without cable connection
1 = With cable connection
This pin is used to indicate the status of the Link connection when
power up reset latch high
0 = With link
1 = Without link
I HP Auto-MDIX Control
(D) 1: Disable auto mode
0: Enable HP Auto-MDIX mode
- Not connect
9
Final
Version: DM9161CIIII-DS-F01
February 22, 2012

Share Link: 