EtronTech
CLK
ADDRESS
C OM M A ND
T0
T1
Bank,
Col A
READ A
NOP
T2
NOP
EM636327
T3
T4
T5
T6
T7
T8
NOP
Bank (s)
Precharge
tRP
NOP
NOP
Bank,
Row
Activate
NOP
CAS# latency=1
tCK1, DQ's
CAS# latency=2
tCK2, DQ's
CAS# latency=3
tCK3, DQ's
DOUT A0
DOUT A1 DOUT A2
DOUT A3
DOUT A0
DOUT A1 DOUT A2
DOUT A3
DOUT A0
DOUT A1 DOUT A2
DOUT A3
Read to Precharge (CAS# Latency = 1, 2, 3)
6 Read and AutoPrecharge command
(RAS# = "H", CAS# = "L", WE# = "H", DSF = "L", BS = Bank, A9 = "H", A0-A7 = Column Address)
The Read and AutoPrecharge command automatically performs the precharge operation after
the read operation. Once this command is given, any subsequent command cannot occur within a
time delay of {tRP(min.) + burst length}. At full-page burst, only the read operation is performed in
this command and the auto precharge function is ignored.
7 Write command
(RAS# = "H", CAS# = "L", WE# = "L", DSF = "L", BS = Bank, A9 = "L", A0-A7 = Column Address)
The Write command is used to write a burst of data on consecutive clock cycles from an active
row in an active bank. The bank must be active for at least tRCD(min.) before the Write command is
issued. During write bursts, the first valid data-in element will be registered coincident with the Write
command. Subsequent data elements will be registered on each successive positive clock edge
(refer to the following figure). The DQs remain with high-impedance at the end of the burst unless
another command is initiated. The burst length and burst sequence are determined by the mode
register, which is already programmed. A full-page burst will continue until terminated (at the end of
the page it will wrap to column 0 and continue).
T0
T1
T2
T3
T4
T5
T6
T7
T8
CLK
C OM M A ND
NOP
WRITE A
NOP
NOP
NOP
NOP
NOP
NOP
NOP
DQ0 - DQ3
DIN A0
DIN A1
The first data element and the write
are registered on the same clock edge.
DIN A2
DIN A3
don't care
Extra data is masked.
Burst Write Operation (Burst Length = 4, CAS# Latency = 1, 2, 3)
Any Write performed to a row that was opened via an BankActivate & Masked Write Enable
command is a masked write (Write-Per-Bit). Data is written to the 32 cells (bits) at the selected
column location subject to the data stored in the Mask register. The overall mask consists of the
DQM inputs, which mask on a per-byte basis, and the Mask register, which masks also on a per-bit
basis. This is shown in the following block diagram.
Preliminary
9
December 1998

Share Link: 