IDT72255LA/72265LA SUPERSYNC FIFO™
8,192 x 18, 16,384 x 18
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
change in level will only be noticeable if EF was HIGH before
setup. During this period, the internal read pointer is initialized
to the first location of the RAM array.
When EF goes HIGH, Retransmit setup is complete and
read operations may begin starting with the first location in
memory. Since IDT Standard mode is selected, every word
read including the first word following Retransmit setup re-
quires a LOW on REN to enable the rising edge of RCLK. See
Figure 11, Retransmit Timing (IDT Standard Mode), for the
relevant timing diagram.
If FWFT mode is selected, the FIFO will mark the beginning
of the Retransmit setup by setting OR HIGH. During this
period, the internal read pointer is set to the first location of the
RAM array.
When OR goes LOW, Retransmit setup is complete; at the
same time, the contents of the first location appear on the
outputs. Since FWFT mode is selected, the first word
appears on the outputs, no LOW on REN is necessary.
Reading all subsequent words requires a LOW on REN to
enable the rising edge of RCLK. See Figure 12, Retransmit
Timing (FWFT Mode), for the relevant timing diagram.
For either IDT Standard mode or FWFT mode, updating
of the PAE, HF and PAF flags begin with the rising edge of
RCLK that RT is setup. PAE is synchronized to RCLK, thus
on the second rising edge of RCLK after RT is setup, the PAE
flag will be updated. HF is asynchronous, thus the rising
edge of RCLK that RT is setup will update HF. PAF is
synchronized to WCLK, thus the second rising edge of
WCLK that occurs tSKEW after the rising edge of RCLK that
RT is setup will update PAF. RT is synchronized to RCLK.
11