TLE 6368 / SONIC
tCW=tCW
tOW=tCW
definition
closed window
open window
tSR = tOW/2
(not the same scale)
reset delay time without trigger
tWDR = tRES
(not the same scale)
definition
reset start delay time after window
watchdog timeout
reset duration time after window
watchdog time-out
tECW
fOSC=fOSCmax t EOW, w.c.= ( tCW+tOW )(1-)
worst cases
fOSC=fOSCmin t ECW, w.c.= tCW (1+)
t EOW = end of open window
t OWmin
Minimum open window time: t OWmin= tOW - * ( tOW + 2* tCW )
Example with:
tCW=128ms
=25% (oscillator deviation)
tECW, w.c. = 128(1.25) = 160ms
tEOW, w.c = (128+128)(0.75) = 192ms
towmin = 32ms
Figure 6 Window watchdog timing definition
Figure 6 shows some guidelines for designing the watchdog trigger timing taking the
oscillator deviation of different devices into account. Of importance (w.c.) is the
maximum of the closed window and the minimum of the open window in which the
trigger has to occur.
The length of the OW and CW can be modified by SPI command. If a change of the
window length is desired during the Watchdog function is operating please send the SPI
command with the new timing with a ’Watchdog trigger Bit’ D15=1.In this case the next
CW will directly start with the new length.
A minimum time gap of > 1/48 of the actual OW/CW time between a ’Watchdog disable’
and ’Watchdog enable’ SPI-command should be maintained. This allows the internal
Watchdog counters to be resetted. Thus after the enable command the Watchdog will
start properly with a full CW of the adjusted length.