Table 3 (continued)
Command
Syntax
Description
Input
Kill Memory
Load Program
Move Program
Next
Output Data
Read File
Show
Time
UART
Version
Write Hex File
I(Port Address)
Inputs one byte specified by (Port Address). Entering a space
inputs one byte; a C causes bytes to be continuously entered.
A Carriage Return terminates the continuous mode.
K(n) <ENTER>
This command erases the designated sector of Flash
memory. Only sectors of Flash memory which are not write
protected may be erased. The message "Unkown memory
section or write protected" will be displayed if you attempt to
erase a protected area of memory.
L(Source Start Add)(Source End Add) This command loads the data from the designated
(Target Start Add)<ENTER>
program memory location into the selected data memory
address.
M(Source Start Add)(Source End Add) The "M" command moves a block of data from one data
(Target Start Add)<ENTER>
memory address to another.
N [Add]<Enter>
This command permits you to step through your application
program one instruction at a time. Step from one instruction
to the next by pressing the space bar. Enter a Carriage
Return to exit single-step operation.
O(I/O Address) (byte)<ENTER>
Output the indicated byte to the selected I/O address.
R[Offset Address] <ENTER>
The "R" command permits .Hex files to be downloaded from
the host, normally a Personal Computer. This command may
be ommited if a zero offset address is needed.
S[Register]<ENTER>
This command displays the contents of the listed register. If
no register value is listed, the contents of all registers will be
displayed.
T<ENTER>
This command is used to start the Tele-Controller's Real
Time Clock. The TC-Monitor first asks if you wish to Reset
the Real Time Clock; enter Y for yes and N for no. If you
enter No, you will return to the TC-Monitor prompt. If you
select Yes the TC-Monitor will prompt you to enter a new
Year, Month, Day, Hour and Minute.
U<ENTER>
This command permits direct communications with the
modem. This permits you to enter "AT" modem commands
directly to the modem by using terminal emulation software.
To end communications with the modem type the # character
followed by <ENTER>.
V<ENTER>
This command displays the revision level of the TC-Moniltor.
The format will be "V 1.00-ROM, Xecom, 10/10/94. Note: If
you are using an updated version of the TC-monitor stored in
Flash memory the revision level will be shown as V 1.xx-
Flash, Xecom, 1/1/95.
W(Start Add) (End Add) <ENTER>
This command is used to upload the contents of the program
memory in the controller to the host. To upload contents of
data memory into program memory it must first be loaded
into an overlapped memory section. If the listed starting
address is greater than the ending address, the TC-Monitor
will roll over to address zero when completed with address
FFFF and continue until the ending address is reached.