![](/html/Fujitsu/828649/page32.png)
MB86615
2.6.2 Sending Operation
(1) Start Sending Operation
Parameter
IDIR fall to ILWRE fall time
ICLK rise to ILWRE fall time
ILWRE fall to IV fall time
IV setup time
Data setup time
Data hold time
Symbol
tSDIR
tSIDIR
tILIV
tSIV
tSD
tHD
Min.
—
—
0
40
20
0
Value
Max.
tICLK + 125
40
—
—
—
—
Unit
ns
ns
ns
ns
ns
ns
ICLK
IDIR
ILWRE
IV
ID7 to ID0
tSDIR
tSIDIR
tILIV
tSIV
1
tHD
tSD
2
3
32