MB86615
(2) End Receiving Operation
Parameter
ICLK rise to ILWRE rise
Data output disable time
ILWRE negate time*1
IV rise to ICRCE rise time*2
Symbol
tWREL
tZD
tWREH
tERRH
Min.
—
0
6 tICLK
—
Value
Max.
40
50
—
40
*1: This device negates the ILWRE signal upon completion of reading each packet of data.
*2: The ICRCE signal is asserted only when a CRC error is detected in data received.
Unit
ns
ns
ns
ns
ICLK
IDIR
ILWRE
IV
ID7 to ID0
ICRCE
tWREL
N−2
N−1
tWREH
tZD
N
tERRH
Hi − Z
38