DC/DC Converter
TSC Series
40 to 2500 Watt
Input Specifications
Inrush current 20x nominal input current typ.
Inrush current limiting
AC Input: standard
DC Input: with option ‘‘i’’
Input current at no load 3 % full load typ.
Max ripple of dc input voltage 10 % pk-pk
Start-up delay time 100 ms typ. (softstart)
Hold up time
230 VAC Input: 15 ms typ.
115 VAC Input: 7 ms typ.
Output Specifications
Output voltage range adjustable (refer topmodel selection table)
Regulation
– Input variation ±10% ±0.1 % max.
– Load variation 10–90% ±0.2 % max.
Ripple and noise (20 MHz bandwidth) <1 % Vout +30 mVpk-pk max.
Transient response to ±1% 2 ms
Dynamic response 6 % typ.
Output current limitation 105 – 110 % of Iout max.
Short circuit protection constant current, (automatic recovery)
Overvoltage protection 105 % of Vout max.
Remote sense standard for all models
General Specifications
Temperature ranges
– Operating –20°C to +75°C
– Optional –40°C to +75°C
– Storage –40°C to +85°C
Derating 3.5 %/K above +55°C
Temperature coefficient 0.02 %/°C typ.
Efficiency
Models with 5VDC output: 70 % typ.
Other models: 85 % typ.
Switching frequency 33 kHz typ.
Isolation voltage (60 sec.)
– Models with input voltage <75 VDC:
– Input / Output 1’500 VDC
– Input / Case 1’500 VDC
– Output / Case 1’000 VDC
– Models with input voltage >80 VDC and AC models:
– Input / Output 3’000 VDC
– Input / Case 3’000 VDC
– Output / Case 1’000 VDC
Isolation resistance
– Input / Output (500VDC) >10 MOhm
Reliability /calculated MTBF (MIL-HDBK-217F, at +40°C, ground benign) >100’000 h
Safety standards UL 60950-1, IEC/EN 60950-1
Electromagnetic compatibility (EMC), emissions EN 55022, class B, FCC part 15, level B
Electromagnetic compatibility (EMC), immunity EN 61000-6-2: 2005
Connection H15 male connector (DIN 41612)
(screw terminal for output curret>50A)
Environmental compliance – Reach www.tracopower.com/products/tsc-reach.pdf
– RoHS RoHS directive 2011/65/EU
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.