#7 Slew_Rise & Slew_Fall Of Single Waveform:
Rise and fall slew rate are measured single waveform between 0.8V and 2.0V on the
rising and falling edges of the clock.
(Reference CK505 spec page.20~22)
#8 Duty Cycle Of Single Waveform :
Duty cycle specification is between 45 and 55%.
(Reference CK505 page.20~23)
#4 Cycle to Cycle jitter :
(Reference CK505 spec page.20~23 & JEDEC JESD65-A page.13)