Technical Note
Description of Functions
1) PWM current mode DC/DC converter
While BD6583MUV-A is power ON, the lowest voltage of LED1, 2, 3, 4, 5, 6 is detected, PWM duty is decided to be
0.5Vand output voltage is kept invariably. As for the inputs of the PWM comparator as the feature of the PWM current
mode, one is overlapped with error components from the error amplifier, and the other is overlapped with a current sense
signal that controls the inductor current into Slope waveform to prevent sub harmonic oscillation. This output controls
external Nch Tr via the RS latch. In the period where external Nch Tr gate is ON, energy is accumulated in the external
inductor, and in the period where external Nch Tr gate is OFF, energy is transferred to the output capacitor via external
SBD.BD6583MUV-A has many safety functions, and their detection signals stop switching operation at once.
2) Soft start
BD6583MUV-A has soft start function.
The soft start function prevents large coil current.
Rush current at turning on is prevented by the soft start function.
After RSTB is changed LH, when PWMPOW is changed LH, soft start becomes effective for within 1ms and soft start
doesn't become effective even if PWMPOW is changed LH after that.
And, when the H section of PWMPOW is within 1ms, soft start becomes invalid when PWMPOW is input to H more than
three times. The invalid of the soft start can be canceled by making RSTB L.
3) FAILSEL pin
When the error condition occurs, boost operating is stopped by the protection function, and the error condition is avoided.
On that occasion, the way to stop of boost operating by the protection function can be selected with FAILSEL pin. Details
are as shown in Fig.29, 30.
After power ON, when the protection function is operating under about 1ms have passed, the stop state of the boost
operating can be held through FAILSEL is H, the stop state can reset through RSTB is L.
And, boost operating is stopped when the protection function is operating through FAILSEL is L, but when the protection
function becomes un-detect, boost operating is started again. It never keeps holding the stop state of boost operating.
In PWM control by PWMDRV can’t use this function.
When it is off over 10ms on PWM control by PWMPOW using this function, it may be stopped the boost
operating as over current protection work at off on PWMPOW=L.
Object of protect function is as shown below.
Over-voltage protection
External SBD open detect
Thermal shutdown
LED terminal over-voltage protection
Over current limit
<FAILSEL=H>
RSTB
“H”
FAILSEL
about 1ms
un-operating range
Protection
function
Boost off
operating
un-detection
detection
un-detection
normal operating
boost stop
<FAILSEL=L>
RSTB
FAILSEL
about 1ms
“L” un-operating range
Protection
function
un-detectio
Boost off
operating
normal operating
detection
un-detection
boost stop
normal
operating
off
off
< When it is off on PWMPOW>
normal operating
RSTB
PWMDRV
PWMPOW
Output
voltage
Coil current
FAILSEL
function
invalid
< When it is off on RSTB>
normal
RSTB
PWMDRV
PWMPOW
Output
voltage
Coil current
FAILSEL
function
invalid
valid
Fig.29 FAILSEL operating description
Fig.30 FAILSEL=H light off control