This description applies to firmware version 2.30 or later. The bus coupler is the link between a PROFINET network and the Inline installation system. In addition, it is used to acquire and output digital signals.
Up to 61 Inline devices can be connected at any point to an existing PROFINET network using the bus coupler.
The bus coupler and the Inline devices form a station with a maximum of 63 local bus devices. Here, the inputs and outputs of the bus coupler together form the first local bus device.


FEATUREs
– 2 x Ethernet twisted pair according to 802.3 with auto
   negotiation and auto crossover
– Transmission speed of 100 Mbps
– IP parameter setting using the PROFINET controller
– Connection to the PROFINET network via 8-pos. RJ45
   socket
– Electrical isolation between Ethernet interface and logic
– Ethernet TCP/IP (100 Base-TX, Management via
   SNMP)
– Connection of up to 61 other Inline devices
– Connection of a maximum of 16 PCP devices
– Supported protocols: SNMPv1, TFTP, PROFINET,
   LLDP and MRP (from firmware 3.21)
– PROFINET IRT (Firmware 4.00 or later)
– Conformance with PROFINET specification V2.3
   (Firmware 4.00 or later)
– PROFINET Netload Class III (Firmware 4.00 or later)
– 8 digital inputs, 4 digital outputs
– Automatic detection of the transmission speed in the
   local bus (500 kbps or 2 Mbps)
– Diagnostic and status indicators
– Hardware version 02 or later:
   Approved for use in zone 2 potentially explosive areas


Número de pieza
componentes Descripción
PDF
Fabricante
PROFINET bus coupler, 8 inputs, 24 V DC, 4 outputs, 24 V DC, 500 mA, complete with I/O connectors
Ver
Phoenix Contact
Axioline F digital input and output module, 16 inputs, 24 V DC, 16 outputs, 24 V DC, 500 mA, 1-wire connection technology
Ver
Phoenix Contact
Maximum allowable continuous DC voltage V DC 24 V
Ver
Shanghai Leiditech Electronic Technology Co., Ltd
24-BIT I/O EXPANDER
Ver
Renesas Electronics
24-BIT I/O EXPANDER
Ver
MITSUBISHI ELECTRIC
Single Outputs from 3.3 V to 24 V
Ver
XP Power Limited
TeSys K control relay - 4 NO - <= 690 V - 24 V DC standard coil
Ver
Schneider Electric
TeSys K control relay - 4 NO - <= 690 V - 24 V DC standard coil
Ver
Schneider Electric
TeSys K control relay - 4 NO - <= 690 V - 24 V DC standard coil
Ver
Schneider Electric
Ultrasonic sensor - analog - current (mA) - 30 mm barrel - 15-24 V DC
Ver
Schneider Electric

Share Link: GO URL

EnglishEnglish Korean한국어 Chinese简体中文 Japanese日本語 Russianрусский

All Rights Reserved© datasheetbank.com  [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]