Features
• ESD / Transient protection of high speed data lines exceeding
– IEC61000-4-2 (ESD): ±20 kV (air / contact)
– IEC61000-4-4 (EFT): 2.5 kV / 50 A (5/50 ns)
– IEC61000-4-5 (surge): 3 A (8/20 μs)
• Maximum working voltage: VRWM = 5.3 V
• Ultra low capacitance: CL = 0.4 pF (typical)
• Low clamping voltage, low dynamic resistance RDYN = 0.6 Ω (typical)
• Very small form factor down to 0.62 x 0.32 x 0.31 mm3
• Pb-free (RoHS compliant) and halogen free package
APPLICATION Examples
• USB 2.0, Mobile HDMI Link, MDDI, MIPI, etc.
• HDMI, DisplayPort, DVI, Ethernet, Firewire, S-ATA