AEN
String Move
FIFO Not Empty
IOCHRDY
IOR
10us (max)
24ns (max)
FIGURE 33 - VALID I/O READ READY CYCLE
IOCHRDY Timer
The 10Fs IOCHRDY Timer is initialized when
IOCHRDY is active. The timer count sequence
is activated when IOCHRDY goes inactive. If
IOCHRDY becomes active before the 10Fs time-
out has elapsed, the timer is stopped and the
count is re-initialized. If IOCHRDY is still inactive
when the 10Fs time-out occurs, the timer stops,
the time-out error bit is set, IOCHRDY is re-
asserted, and the string move bit is reset (Figure
34).
AEN
String Move
FIFO Not Empty
IOCHRDY
IOR
IOCHRDY Time-out
10us
Start
Timer
IOCHRDY
Error
FIGURE 34 - IOCHRDY 10FS TIME-OUT
64