datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

M27V402 Ver la hoja de datos (PDF) - STMicroelectronics

Número de pieza
componentes Descripción
Lista de partido
M27V402 Datasheet PDF : 15 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
M27V402
Table 9. Programming Mode DC Characteristics (1)
(TA = 25 °C; VCC = 6.25V ± 0.25V; VPP = 12.75V ± 0.25V)
Symbol
Parameter
Test Condition
Min
Max
Unit
ILI
Input Leakage Current
0 VIN VCC
±10
µA
ICC
Supply Current
50
mA
IPP
Program Current
E = VIL
50
mA
VIL
Input Low Voltage
–0.3
0.8
V
VIH
Input High Voltage
2
VCC + 0.5
V
VOL
Output Low Voltage
IOL = 2.1mA
0.4
V
VOH Output High Voltage TTL
IOH = –400µA
2.4
V
VID
A9 Voltage
11.5
12.5
V
Note: 1. VCC must be applied simultaneously with or before VPP and removed simultaneously or after VPP.
Table 10. Programming Mode AC Characteristics (1)
) (TA = 25 °C; VCC = 6.25V ± 0.25V; VPP = 12.75V ± 0.25V)
t(s Symbol
Alt
Parameter
Test Condition Min
uc tAVEL
tAS
Address Valid to Chip Enable Low
2
rod tQVEL
tDS
Input Valid to Chip Enable Low
2
P tVPHEL
tVPS VPP High to Chip Enable Low
2
te tVCHEL
tVCS VCC High to Chip Enable Low
2
le tELEH
tPW
Chip Enable Program Pulse Width
95
so tEHQX
tDH
Chip Enable High to Input Transition
2
b tQXGL
tOES Input Transition to Output Enable Low
2
- O tGLQV
tOE
Output Enable Low to Output Valid
t(s) tGHQZ
tDFP Output Enable High to Output Hi-Z
0
uc tGHAX
tAH
Output Enable High to Address
Transition
0
d Note: 1. VCC must be applied simultaneously with or before VPP and removed simultaneously or after VPP.
ro 2. Sampled only, not 100% tested.
Max Unit
µs
µs
µs
µs
105
µs
µs
µs
100
ns
130
ns
ns
te P Programming
le When delivered (and after each erasure for UV
EPROM), all bits of the M27V402 are in the ’1’
so state. Data is introduced by selectively program-
bming ’0’s into the desired bit locations. Although
only ’0’s will be programmed, both ’1’s and ’0’s can
Obe present in the data word. The only way to
light (UV EPROM). The M27V402 is in the pro-
gramming mode when VPP input is at 12.75V, G ia
at VIH and E is pulsed to VIL. The data to be pro-
grammed is applied to 16 bits in parallel to the data
output pins. The levels required for the address
and data inputs are TTL. VCC is specified to be
6.25V ± 0.25V.
change a ’0’ to a ’1’ is by die exposure to ultraviolet
7/15

Share Link: 