Philips Semiconductors
Enhanced programmable communications
interface (EPCI)
Product specification
SCN2661/SCN68661
ORDERING CODE
PACKAGES
28-Pin Ceramic Dual In-Line Package (cerdip) 0.6” Wide
28-Pin Plastic Dual In-Line Package (DIP) 0.6” Wide
28-Pin Plastic Lead Chip Carrier (PLCC)
BLOCK DIAGRAM
VCC = +5V +5%
Commercial
0°C to +70°C
Industrial
-40°C to +85°C
SCN2661BC1F28
SCN2661CC1F28
SCN2661BA1F28
SCN2661CA1F28
SCN2661AC1N28
SCN2661BC1N28
SCN2661CC1N28
Contact Factory
SCN2661AC1A28
SCN2661BC1A28
SCN2661CC1A28
Contact Factory
DWG #
0589B
SOT117-2
SOT261-3
DATA BUS
D0–D7
DATA BUS
BUFFER
SNE/DLE CONTROL
SYN 1 REGISTER
SYN 2 REGISTER
DLE REGISTER
RESET
A0
A1
R/W
CE
BRCLK
TxC/SYNC
RxC/BKDET
DSR
DCD
CTS
RTS
DTR
TxEMT/*
DSCHG
NOTES:
* Open–drain output pin.
OPERATION CONTROL
MODE REGISTER 1
MODE REGISTER 2
COMMAND REGISTER
STATUS REGISTER
BAUD RATE
GENERATOR
AND
CLOCK CONTROL
MODEM
CONTROL
TRANSMITTER
TRANSMIT DATA
HOLDING REGISTER
TRANSMIT
SHIFT REGISTER
RECEIVER
RECEIVE DATA
HOLDING REGISTER
RECEIVE
SHIFT REGISTER
TxRDY*
TxD
RxRDY*
RxD
SD00078
ABSOLUTE MAXIMUM RATINGS1
SYMBOL
TA
TSTG
PARAMETER
Operating ambient temperature2
Storage temperature
All voltages with respect to ground3
RATING
Note 4
-65 to +150
-0.5 to +6.0
UNIT
°C
°C
V
NOTES:
1. Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only and
functional operation of the device at these or at any other condition above those indicated in the operation section of this specification is not
implied.
2. For operating at elevated temperatures, the device must be derated based on +150°C maximum function temperature.
3. This product includes circuitry specifically designed for the protection of its internal devices from the damaging effect of excessive static
charge. Nonetheless, it is suggested that conventional precautions be taken to avoid applying any voltages larger than the rated maxima.
4. Over recommended free-air operating temperature range and supply voltage range unless otherwise specified. For conditions shown as MIN
or MAX, use the appropriate value specified under recommended operating conditions.