DAP011/DAP011C
Soft−start and Fault Timer
The Speedking features an internal soft−start circuit
activated during the power on sequence (PON) but also
during skip cycle to reduce the acoustical noise (see skip
cycle section). As soon as VCC reaches VCCON, the peak
current is gradually increased from nearly zero up to the
maximum clamping level (e.g. 1.0 V / Rsense). The peak
current is clamped at 1.0 V / Rsense through the entire
soft−start period until the supply enters regulation.
Figure 30 shows a typical startup shot.
VCCON
12 V
6.9V
timer 3
10% of Timer or 500 ms at Skip Mode
Figure 30. Soft−start is Activated During a Startup Sequence an OCP Condition
(or During Skip−Cycle − 500 ms Skip Ramp)
VtimS+S
+
Vtimf+ault
+
VDD
soft−start ended
fault
Itim
skip, soft−start
IpFlag
power on reset
Figure 31. Soft−start is Activated During a Startup
Sequence, an OCP Condition (or During Skip−Cycle
− 500 ms Skip Ramp)