Digital Line to POTS Interface
CMX605
1.6 Application Notes
When using the Tone/FSK bit (bit 6) of the MODE Register, each tone starts from VBIAS, and
returns to VBIAS before ending:
Figure 5 Tone Starting and Stopping
When switching between tones in the same column (bits 4 - 7 or bits 0 - 3) of the TX TONES
Register), the transition will be phase continuous. However, switching to the “OFF” state will
immediately take the output of that tone generator to VBIAS.
Figure 6 Tone Changing
TX TONES Register decodes which do not have a frequency allocated are indicated by “-“ in the
Tone Field tables. These values should not be used.
1.6.1 Telecom Tones
The following tables give the hex codes to be programmed into the particular tone field location
for various telecommunications systems applications. The tables are not exhaustive, but list the
more commonly used tones.
Ringing Signals
(f ± 2.5%)
(Hz)
Off
16.7
20
25
35
40
50
Field 0
(Hex)
$00
$01
$02
$03
$04
$05
$06
© 2001 Consumer Microcircuits Limited