Philips Semiconductors
Memory controller
Objective specification
SAA4952WP
Table 13 Horizontal programming range of CLV, HWE1 and HVACQS
Nr (programmed start value of corresponding signal) not equal Nf (programmed stop value of corresponding signal).
ACQUISITION FREQUENCY
(MHz)
12
13.5
16
18
TIMING EQUATIONS
CLVr = (4Nr + 2)LLA
CLVf = (4Nf + 2)LLA
HWE1r = (2Nr + 2)LLA
HWE1f = (2Nf + 2)LLA
HVACQS1 = (4N(1) + 2)LLA
HVACQS2 = (4M(2) + 2)LLA
CLVr = (4Nr + 2)LLA
CLVf = (4Nf + 2)LLA
HWE1r = (2Nr + 2)LLA
HWE1f = (2Nf + 2)LLA
HVACQS1 = (4N(1) + 2)LLA
HVACQS2 = (4M(2) + 2)LLA
CLVr = (4Nr + 2)LLA
CLVf = (4Nf + 2)LLA
HWE1r = (2Nr + 2)LLA
HWE1f = (2Nf + 2)LLA
HVACQS1 = (4N(1) + 2)LLA
HVACQS2 = (4M(2) + 2)LLA
CLVr = (8Nr + 2)LLA
CLVf = (8Nf + 2)LLA
HWE1r = (4Nr + 2)LLA
HWE1f = (4Nf + 2)LLA
HVACQS1 = (8N(1) + 2)LLA
HVACQS2 = (8M(2) + 2)LLA
PROGRAMMING RANGE
0 ≤ Nr < 191
0 ≤ Nf < 191
0 ≤ Nr < 383
0 ≤ Nf < 383
0 ≤ N < 191
0 ≤ M < 191
0 ≤ Nr < 215
0 ≤ Nf < 215
0 ≤ Nr < 431
0 ≤ Nf < 431
0 ≤ N < 215
0 ≤ M < 215
0 ≤ Nr < 255
0 ≤ Nf < 255
0 ≤ Nr < 511
0 ≤ Nf < 511
0 ≤ N < 255
0 ≤ M < 255
0 ≤ Nr < 143
0 ≤ Nf < 143
0 ≤ Nr < 287
0 ≤ Nf < 287
0 ≤ N < 143
0 ≤ M < 143
Notes
1. N: programmed value of HVACQS1 pulse.
2. M: programmed value of HVACQS2 pulse.
The programmed values include the MSB setting contained in HAMSBDEL.
For SDAF = 1 the factors in front of Nr and Nf are doubled.
For EXTLLA = 1 the equations for LLA = 18 MHz are valid.
The programming margins depend on the used external clock frequency.
L----L---A---1-E----X----T-- × N ≤ 64 µs
1997 Jun 10
15