MIL-PRF-19500/562C
3.2 Associated specification. The individual item performance requirements shall be in accordance with MIL-PRF-19500, and as
specified herein.
3.3 Abbreviations, symbols, and definitions. Abbreviations, symbols, and definitions used herein shall be as specified in MIL-PRF-
19500.
3.4 Interface requirements and physical dimensions. The interface requirements and physical dimensions shall be as specified in
MIL-PRF-19500 and on figure 1 (TO-204AA) and figures 2 and 3 (JANHC and JANKC) herein.
3.4.1 Lead finish. Lead finish shall be solderable in accordance with MIL-PRF-19500, MIL-STD-750 and herein. Where a choice of
lead finish is desired, it shall be specified in the acquisition document (see 6.2).
3.4.2 Internal construction. Multiple chip construction shall not be permitted.
3.5 Marking. Devices shall be marked in accordance with MIL-PRF-19500.
3.6 Electrical performance characteristics. Unless otherwise specified, the electrical performance characteristics are as specified in
1.3, 1.4, and table I herein.
3.7 Electrostatic discharge protection. The devices covered by this specification require electrostatic protection.
3.7.1 Handling. MOS devices must be handled with certain precautions to avoid damage due to the accumulation of static charge.
The following handling practices shall be followed:
a. Devices shall be handled on benches with conductive handling devices.
b. Ground test equipment, tools, and personnel handling devices.
c. Do not handle devices by the leads.
d. Store devices in conductive foam or carriers.
e. Avoid use of plastic, rubber, or silk in MOS areas.
f. Maintain relative humidity above 50 percent if practical.
g. Care shall be exercised, during test and troubleshooting, to apply not more than maximum rated voltage to any lead.
h. Gate must be terminated to source, R 100 k, whenever bias voltage is to be applied drain to source.
3.8 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table I.
3.9 Qualification. Devices furnished under this specification shall be products that are authorized by the qualifying activity for listing
on the applicable qualified products list before contract award (see 4.2 and 6.3 ).
4. VERIFICATION
4.1 Classification of Inspections. The inspection requirements specified herein are classified as follows:
a. Qualification inspection (see 4.2).
b. Screening (see 4.3)
c. Conformance inspection (see 4.4).
4.2 Qualification inspection. Qualification inspection shall be in accordance with MIL-PRF-19500 and herein. Alternate flow is allowed
for qualification inspection in accordance with figure 4 of MIL-PRF-19500.
4.2.1 Group E inspection. Group E inspection shall be conducted in accordance with MIL-PRF-19500 and herein.
6