Measurement Equipment :
Clock Rise Time / Fall Time Are Measured by Tektronix® 6804B with Single-ended Probe
- Mainframe with 8.0GHz Bandwidth
- Mainframe with 20GS/s Sampling Rate
- P7240 Active Probe with 4.0GHz Bandwidth (input: 1.0pF / 20K-ohm)
Clock Jitter & Duty Cycle Are Measured by Tektronix® 6804B with Differential Probe
- P7330 Differential Active Probe with 3.5GHz Bandwidth (input: 0.5pF / 100K-ohm)
- Tektronix® Jitter Analysis 3® Jitter Measurement Software
Measurement Environment :
- Test board
Measurement Item :
Differential Clock
- Slew_Rise & Slew_Fall
- Vcross & ΔVcross
- Cycle to Cycle jitter
- Vmax & Vmin
- Duty Cycle
Single-end Clock
- Slew_Rise & Slew_Fall
- Duty Cycle
- Cycle to Cycle jitter
Measurement Summary
From the measurement shown as follows, RTM875N-397 works good and meets all CLK Spec.